Perfect hinged doors
Since 40 years – time-proven technology

Whether as service room, cold room or freezer room doors – cool it doors impress with high-quality materials, perfect workmanship and optimum equipment options. The unique range of variants ensures that they can be used in different areas, for example in temperature-controlled processing and storage or wherever cooling or freezing is not important, such as in social, operating and hygiene rooms.

cool it D-Series
  • Bild Drehtür D8
  • Bild Drehtür D12
  • Bild Drehtür D12
  • D8 D12 D16 The safe solution for all cooling zones

    With three different leaf thicknesses of 80, 120 and 160 mm, D-Series hinged doors are designed for use in any temperature range. D8 for cold rooms, D12 for freezer rooms and D16 for blast freezer rooms.

    With absolute reliability and system stability, D-Series hinged doors ensure permanently smooth operating processes and constant temperatures. That is why they are the reliable, easy-to-clean room closure for sensitive areas in temperature-controlled processing and logistics.

    The “Z models” are also available as double-leaf versions.
     

  • D8 D12 D16 Die sichere Lösung für alle Kältezonen

    Mit drei unterschiedlichen Blattstärken von 80, 120 und 160 mm sind Drehtüren der D-Serie auf den Einsatz in jedem Temperaturbereich abgestimmt. D8 für Kühlräume, D12 für Gefrierräume und D16 für Schockgefrierräume. 

    Mit absoluter Verlässlichkeit und Systemstabilität sorgen Drehtüren der D-Serie für dauerhaft reibungslose Betriebsabläufe und konstante Temperaturen. Sie sind damit der zuverlässige, leicht zu reinigende Raumabschluss für sensible Bereiche in der temperaturgeführten Verarbeitung und Logistik

  • D8 D12 D16 Die sichere Lösung für alle Kältezonen

    Mit drei unterschiedlichen Blattstärken von 80, 120 und 160 mm sind Drehtüren der D-Serie auf den Einsatz in jedem Temperaturbereich abgestimmt. D8 für Kühlräume, D12 für Gefrierräume und D16 für Schockgefrierräume. 

    Mit absoluter Verlässlichkeit und Systemstabilität sorgen Drehtüren der D-Serie für dauerhaft reibungslose Betriebsabläufe und konstante Temperaturen. Sie sind damit der zuverlässige, leicht zu reinigende Raumabschluss für sensible Bereiche in der temperaturgeführten Verarbeitung und Logistik

  • D-Series Shortlist
    Series models
    D8, ZD8, D12, ZD12, D16, ZD16
    Application areas
    Cold rooms, freezer rooms, blast freezer rooms
  • D-Serie Shortlist
    Serienmodelle
    D8, ZD8, D12, ZD12, D16, ZD16
    Einsatzorte
    Kühlräume, Gefrierräume, Schockgefrierräume
  • D-Serie Shortlist
    Serienmodelle
    D8, ZD8, D12, ZD12, D16, ZD16
    Einsatzorte
    Kühlräume, Gefrierräume, Schockgefrierräume
cool it DM-Series
  • Bild Drehtür D8M
  • D12M Drehtür
  • D8M D12M Self-closing hinged cold room door with magnetic hold-closed function

    Hinged doors in the cool it DM series not only offer perfect handling and ease of use, they also leave nothing to be desired in terms of hygiene and safety. This makes them suitable for smooth, continuous operation in numerous areas of the company – whether in normal temperature ranges, refrigerated or frozen environments

  • D8M D12M Selbstschließende Kühlraumdrehtür mit Magnetgriffstange

    Drehtüren der DM-Serie von cool it bieten nicht nur ein perfektes Handling und hohen Bedienkomfort, sie lassen auch in Sachen Hygiene und Sicherheit keine Wünsche offen. Damit eignen sie sich für den reibungslosen Dauerbetrieb in zahlreichen Unternehmensbereichen – egal ob Normaltemperaturbereich, Kühl- oder Gefrierumgebung

  • DM-Series Shortlist
    Series models
    D8M, D12M
    Application locations
    Business premises, cold rooms, freezer rooms
  • DM-Serie Shortlist
    Serienmodelle
    D8M, D12M
    Einsatzorte
    Betriebsräume, Kühlräume, Gefrierräume
cool it D16DD-Series - The door for extreme low temperatures
  • D16DD
  • D16DD The freezer room door for the highest demands, suitable for the temperature range down to -80°C

    The double PVC cold break profile with 80 mm spacing to form a hollow chamber provides additional insulation through a stationary and heated air layer in the cavity. 
    An additional sill heater is positioned centrally under the hollow chamber to heat the sill plate and generate the heated air.
     

  • D16DD-Series Shortlist
    Series model
    D16DD
    Place of use
    Shock freezer rooms
cool it B-Series
  • Bild Drehtür B4
  • B4F Tür
  • D4G Drehtür
  • B4 B4F B8 The hygienic multi-purpose doors for service rooms

    Hinged doors from the B series set real standards in terms of product quality, innovation, handling, durability and hygiene. 
    They also meet the highest demands in terms of individuality, thanks to their wide range of variants and colors. Cool it service room doors are end-coated.
     

  • B-Series Shortlist
    Series models
    B4, B4F, B8
    Application areas
    Business premises with cleaning requirements
cool it B12A-Series
  • Bild Drehtür B12A
  • B12A Stability meets security, the certified external door to DIN EN 14351-1

    The versatile product features make the B12A a reliable, robust and durable external door for any installation situation, regardless of whether it seals off service rooms, cold storage rooms or freezer rooms from the outside. The B12A (door leaf with frame) is also available in various RAL colors and blends in perfectly with the look of the building. Also available with RC2 burglary protection on request.

  • B12A-Shortlist
    Series model
    B12A
    Application area
    External door
Hinged doors
cool it offers you what you need: the best

cool it is one of the largest producers of special doors for the German and international food industry. Whatever type of door you need: Our comprehensive, demand-oriented product portfolio offers you the best the market has to offer. From hinged doors to high-speed doors: cool it has the perfect solution for every application – custom-made.

Hinged doors brochure